PROOF PRESSURE TEST REPORTS
Test Report #1
TITANIUM HEADER P/N 1812-003, used on Hydracon Switch Models 1812-100 and 1801-201.
SWITCH UNIT TESTED: E-B weldment of 1812-001 Housing and 1812-003 Header. Header pressure tested open face.
TEST DATE: 25 FEB. 2004
EQUIPMENT & INSTRUMENTS USED:
- Pressure Vessel: Model 1801-071, made by Hydracon for 1801-200
- Hand Pump: Enerpac P80
- Pressure Gauge: Ashcroft, 6,000 psi (each mark = 50 psi)
- Weighing scale: Acculab digital #GS1-200
CONDITIONS: Ambient temperature: 65 deg F.
PROCEEDURE:
- Unit weight before hydro test: 1.855 oz.
- One unit was bagged and installed in the pressure vessel and filled with mineral oil.
- Pressure was applied to 5,000 psi, and maintained at 4,500 psi +/- 100 psi for one hour
- The unit was removed from pressure vessel, cleaned, and weighed.
- Unit weight after hydro test: 1.855 oz.
OBSERVATIONS & CONCLUSIONS:
- Visual inspection: No visual deformation.
- Change in weight: none (no mineral oil leaked into sealed switch chamber).
Tested By: Alex Pullos, 25 Feb. 2004. ________________________________________
Test Report #2
10,000 PSI TEST
The above test was repeated at 10,000 psi for 4 hours.
OBSERVATIONS & CONCLUSIONS:
- Visual inspection: No visual deformation.
- Change in weight: none (no mineral oil leaked into sealed switch chamber).
Tested By: Alex Pullos, 6 Sept. 2005. ________________________________________
1812-PressureTest.doc
Test Report # 3
Hydracon Switch Model 1800-201.
SWITCH UNIT TESTED:
Hydracon Proximity Switch Model 1800-201, S/N 135.
Pressure tested open face, leadwires were not sealed.
TEST DATE: 23 April 2007
EQUIPMENT & INSTRUMENTS USED:
- Pressure Vessel: Model 1703-099, made by Hydracon
- Hand Pump: Enerpac P80
- Pressure Gauge: 10,000 psi
- Weighing scale: Acculab digital #GS1-200
CONDITIONS:
Ambient temperature: 65 deg F.
PROCEEDURE:
- Unit weight before hydro test: 2.000 oz.
- One unit was bagged in water, installed in the pressure vessel, and filled with water.
- Pressure was applied to 10,000 psi, and maintained at 10,000 psi +/- 100 psi for one hour
- The unit was removed from pressure vessel, wiped cleaned, and weighed.
- Unit weight after hydro test: 2.000 oz.
OBSERVATIONS, TESTING, and CONCLUSIONS:
Visual inspection: No visual deformation.
Tests: Operation: passed
Insulation Resistance: w/ 500vdc: infinity 3 places.
Change in weight: none
Conclusions: 1. No water leaked into the switch.
2. No visible damage due from the 10,000 psi.
Tested By: Alex Pullos, 23 April 2007. ________________________________________